Field guide · Installation Practice & Site Readiness

IP66 vs IP67 vs IK10: What the Ratings Mean on Site

Understand IP66, IP67 and IK10 without confusing jet, immersion and impact tests. Check exact camera ratings, installation conditions and project evidence.

By Anabon Security Inc. — Technical Support · 8 min read · For installers, integrators and dealers

Quick answer: IP describes enclosure ingress tests; IK describes mechanical-impact tests. IP66 and IP67 address different water exposures, so do not automatically rank immersion above jets or infer one from the other. IK10 is a 20 J test classification, not vandal-proof protection or the highest possible IK class. Check the exact product, test/installation conditions and complete assembly against the project’s real hazards.

On this page

What do the two IP digits actually test?

IEC60529 defines the IP code. The first digit6 denotes dust-tight classification; water digits6 and 7 describe different standardized tests. Do not infer jet resistance from an immersion-only marking or convert a lab test into permission for every hose, flood or cleaning process. Obtain exact marking, test evidence and installation conditions for the required exposure; aging, entries and service condition also matter. Read the IEC ingress-protection standard for its defined test scope.

What do the two IP digits actually test?
Marking What it addresses What it does not establish
IP6X Dust-tight classification Corrosion, explosive-dust suitability or every installed entry
IPX6 Powerful water jets under the specified test Every hose distance/pressure, hot water, chemicals or pressure washing
IPX7 Temporary immersion under specified conditions, commonly described as 1 m / 30 min for small enclosures Continuous flooding, every orientation or the separate jet test
IPX9 / separately specified K code A different high-pressure/high-temperature test framework as actually marked Interchangeability of IEC IPX9 and every ISO K marking, or general wash-down approval

Ask how the area is actually cleaned and exposed: temperature, pressure, chemicals, distance, direction and duration. The manufacturer’s exact approval must fit that process. IP66 is not permission to pressure-wash a camera, and IP67 is not a design instruction to leave it sitting in water.

What does an IK rating add that IP does not?

IEC62262 classifies enclosure resistance to specified mechanical impacts. Common levels include IK08 at 5 J, IK09 at 10 J and IK10 at 20 J. The2021 amendment also includes IK11 at 50 J, so IK10 is not the top of the current scale. Product-specific tests and acceptance conditions matter; the code alone does not promise the optics, mount or full recording system survives every attack. Use IEC 62262 with the 2021 amendment for the applicable code levels.

What does an IK rating add that IP does not?
IK code Test impact energy Use in a specification
IK08 5 J Verify the exact declared enclosure and required test conditions
IK09 10 J Compare the actual project requirement and product evidence
IK10 20 J Impact-resistant classification; not vandal-proof or a weapon simulation
IK11 50 J Included by the 2021 amendment; do not assign it to a camera without evidence

Use vandal-resistant with the actual documented rating and limitations, not vandal-proof. A standardized energy is not a guarantee against a stone, kick, bat or hammer in real use. Review the protected parts, mounting, exposed wiring, access, aiming and evidence coverage as a system. Do not assume the enclosure code independently rates every bracket, connector, optical window and function.

Which rating matters on which site?

Decide from the hazard in front of you, not from the highest number in the catalog: what will hit it, and what will wet it.

  • Impact/tampering: assess actual access and threat, compatible mounts and documented IK requirements; no universal10 ft height solves it.
  • Rain/cleaning/water: obtain the actual exposure and exact product/assembly approval. IP67 does not automatically add jet or chemical resistance.
  • Cold: check actual operating/startup and humidity requirements; see the cold-weather installation guide.
  • Salt/chemicals: obtain material, corrosion and cleaning compatibility separately. Metal is not a corrosion certificate.
  • Special environments: ingress codes do not establish hazardous-location approval, hygiene compliance or fire/explosion protection.

How do the ratings read on CASE spec sheets?

The following examples reproduce separate Protection, Housing and operating rows for complete CASE SKUs. Use the IP cameras for installers collection to build a shortlist, then check each complete SKU’s current documentation. Treat them as candidates for further confirmation, not automatic approval for a named site or exposure.

How do the ratings read on CASE spec sheets?
SKU Form Protection Housing Operating conditions Where it fits
CS-I5KS SD-2.8mm 5MP dome, IR 98 ft (30 m), white light 33 ft (10 m) IP67, IK10 Metal+Plastic −31 °F to 149 °F (−35 °C to 65 °C) Confirm actual task, complete assembly, exposure and installation conditions.
CS-I5PS S-2.8mm 5MP dome, IR 98 ft (30 m), audio 1/1, alarm 1/1 IP66, IK08 Metal −40 °F to 149 °F (−40 °C to 65 °C) Confirm actual task, complete assembly, exposure and installation conditions.
CS-I8MS I-2.7-13.5mm 8MP varifocal dome, IR 164 ft (50 m), Advanced AI IP66, IK10 Metal −31 °F to 149 °F (−35 °C to 65 °C) Confirm actual task, complete assembly, exposure and installation conditions.
CS-I8WS S-2.8mm 8MP bullet, IR 164 ft (50 m) IP67 Metal −40 °F to 149 °F (−40 °C to 65 °C) Confirm actual task, complete assembly, exposure and installation conditions.

Keep the full SKU and suffix: CS-I5KS SD-2.8mm differs from CS-I5PS S-2.8mm. The listed CS-I8WS S-2.8mm row has no IK declaration; do not invent one. Resolve conflicting website/catalog/specification values with current written evidence for the exact revision and project before commitment. General category policies are a starting point, not a warranty for every SKU. Confirm the term, exclusions and claim process for the exact model and revision in writing. Project Series items, intercoms, powered accessories and model-specific exceptions need their own confirmation; hard-drive claims follow the applicable drive-manufacturer terms.

Site-survey checklist for ratings

  1. Record actual access, impact risk and required view; agree a mounting solution that addresses both evidence quality and service safety.
  2. Document real water/cleaning exposure, dust, temperature, chemicals and corrosion rather than choose the largest digit.
  3. Obtain exact current marking, scope and installation conditions for the camera and compatible assembly.
  4. Record confirmed limits, missing evidence and project acceptance in the camera schedule.

NEMA vs IP: how do you answer a spec that says “NEMA 4X”?

NEMA enclosure Types and IEC IP codes cover different requirements. Do not convert an IP marking into NEMA4X or infer a UL/CSA certification from a NEMA number. Obtain the actual specified edition, Type/listing, exact product evidence and authorized project acceptance. NEMA’s published comparison expressly does not support converting an IEC IP code into a NEMA Type.

  • Use the project’s actual NEMA/UL/CSA requirement and edition; these labels are not interchangeable declarations.
  • IP and IK rows can be relevant evidence, but do not by themselves satisfy the remaining Type or listing requirements.
  • If proposing an alternative, disclose the gap and use the permitted clarification/substitution process; a consultant’s informal note does not create a product certification.

For a requirement such as NEMA4X, identify the exact required evidence rather than state that IP66/IP67 covers its water/dust portion. Ask for documented compliance or an explicitly permitted alternative and acceptance through the project process. How to read a video surveillance RFP covers traceable compliance and substitution review.

Which installation details protect the rating you specified?

The declared enclosure assumes its applicable test and assembly conditions. Installation, damage, aging or an incompatible entry can affect protection, but do not diagnose every leak as installer error or declare a rating lost/recovered from a photograph alone. Follow approved service and test procedures. For cold-weather sites, include the separate thermal and installation checks in the cold-weather installation guide.

  1. Use compatible specified mounts, entries, glands, boxes and cable seals; protect connectors and preserve required vents/drains.
  2. Follow exact opening, gasket, torque, orientation and cleaning instructions. Do not add generic sealant or substitute fasteners/desiccant without approval.
  3. Set view, access, tamper provisions and safe maintenance from the actual design.
  4. Document the assembly and required checks at handover. Photos support records but are not certification or proof every seal passes.

What to tell your customer

We will state the exact product’s documented IP and IK ratings and their test scope, then design the compatible mount and entries for this location. Those codes do not guarantee immunity to vandalism, flooding, chemicals or every cleaning process. We will identify any missing project requirement before promising acceptance or warranty coverage.

FAQ

Is IP67 better than IP66 for an outdoor security camera?

No automatic ranking applies to the separate jet and immersion tests. Obtain the exact marking and evidence for the actual exposure; do not infer jet approval from an immersion-only code or install a camera in pooling water just because IP67 appears in a catalog. Use the video surveillance RFP guide to record the exact specified marking and required acceptance evidence.

Does IK10 make a camera vandal proof?

No. IK10 is a standardized20 J enclosure-impact classification. It is not a guarantee against a particular weapon, repeated attack, lost aim or every component failing. Specify the actual rating and compatible assembly, assess access and test the required recording task. IK11 also exists in the 2021 amendment.

Can I install an IP66 camera where the crew hoses the area down?

Not from the IP66 label alone. Compare actual cleaning pressure, temperature, chemicals, distance and duration with the exact manufacturer-approved process and complete assembly. Do not equate a lab jet test with unrestricted hose-down or prescribe a K rating as a universal substitute.

Why does a website show a different IP rating than the catalog for the same CASE SKU?

Different revisions, transcription errors or update cycles can cause disagreement, but do not assume the cause or choose the most favorable number. Obtain current exact-SKU/revision documentation and written resolution from Anabon before a project commitment. Keep the discrepancy and approved value in the record.

Does a higher IP or IK rating change the warranty?

General category policies are a starting point, not a warranty for every SKU. Confirm the term, exclusions and claim process for the exact model and revision in writing. Project Series items, intercoms, powered accessories and model-specific exceptions need their own confirmation; hard-drive claims follow the applicable drive-manufacturer terms. A stronger ingress/impact number does not automatically extend a term or make water/impact damage covered. Confirm exact order terms, exclusions and the installer/dealer claim process. General camera/NVR policy is six years and PTZ three years, subject to documented model exceptions.

References

  • Anabon: current exact-model documents
  • IEC: ingress-protection standard
  • IEC62262 consolidated with2021 amendment
  • NEMA: enclosure Types and one-way comparison limitation


Product documents and project support

Match the current product documents to your full equipment schedule before quoting.

Private pricing is available through your approved business account. Confirm the exact model, revision, required functions and written warranty terms for your project.

FOR SECURITY INSTALLERS & INTEGRATORS

Find Your Next Project with Free Bid Alerts

Receive timely email updates about security tenders and project opportunities, organized by the states or provinces you choose. Register your interests below — this service is free.

Free project design guidance, 24/7

Anabon helps installers and integrators with system design and bid preparation. Get free guidance as you plan the project and prepare your proposal.

Call Our Team: +1 289 800 9000
Choose Your States & Request Free Bid Alerts

Where would you like to find your next project?

Choose your country and the states or provinces you want to follow, then submit your request.

Bid Opportunities

Explore Past Security Bid Opportunities

Examples from our archive. The submission deadlines below have passed; these are not open invitations to bid.

Browse all bid opportunities

Are you an end user rather than an installer? For warranty and service, please contact the installer or company that supplied your system. Anabon supports warranty and technical service through our installer, dealer and business-account network.

Scroll to Top