Quick answer: Plan office cameras around the route an incident could take: entry, lift lobby, stairs and garage. Give each view a specific job, separate landlord and tenant access, and test recorded footage in difficult lighting. Floor count alone does not tell you how many cameras to quote.
On this page
Agree where the building system stops
On an office job, the property manager may buy the system while individual tenants control their own suites and networks. Settle that boundary before marking a plan. Identify the person who approves common-area coverage, the IT contact who approves connections and the person who can authorize an export after an incident.
Walk from the public entrance to the tenant door. Mark controlled doors, reception, service entrances and parking routes, including lighting and cable paths. Use a camera schedule template to give each proposed view an evidence task and a responsible approver. A corridor camera must not become an unapproved view into a private office whenever its door opens.
Give each view an evidence task
A broad lobby picture helps explain movement; a tighter entrance view may be needed to examine the person entering. Compare suitable IP cameras after you have defined the scene width and mounting position. Do not choose every lens from the same shelf simply because the housings match.
| Area | Purpose | Test on recorded footage |
|---|---|---|
| Lobby entrance | See entry direction and the approaching person | Walk toward the camera with the exterior door open. |
| Lift lobby or stair landing | Follow movement between circulation routes | Check doors, corners and people crossing together. |
| Garage ramp and pedestrian door | Connect vehicle movement with the pedestrian route | Repeat with headlights and the actual night lighting. |
| Loading or service entrance | Record a delivery and departure | Test with a van parked in its normal unloading position. |
Use the table as a survey checklist, not a fixed camera schedule. A wide foyer, several access routes or a parked vehicle can change the design. Write down where the customer accepts an overview and where they need a closer view; those are different acceptance decisions.
Equipment example: For an entrance-framing review, CS-I4KS L-2.8-12mm is a current CASE example with a 4MP sensor and motorized 2.8–12mm lens in the catalog (physical page 6). Use the lens adjustment to test the agreed lobby scene; it does not guarantee a face result, garage performance or suitability at every mounting point.
Test lifts and garage lighting separately
Elevator-cab work needs coordination with the elevator contractor. Confirm approved mounting, power, communications and service access; do not improvise a connection into lift equipment. A lift-lobby camera and a cab camera show different parts of the journey. Explain any gap rather than promising that one replaces the other.
At the garage, test an actual vehicle entering from daylight and again after dark. Review the saved clip, not just a live-view tile. Adjust position, framing and supported exposure settings to balance the useful subject against bright openings. A WDR label is not an acceptance test. Keep a separate pedestrian-door view if the ramp camera cannot show that doorway clearly.
Budget the network and recording together
Have IT approve the camera-network path, controlled access and any tenant-network interconnection. Check PoE device demand, switch total and uplink load; connector count alone is not enough. Select the network video recorder against the full schedule, supported streams, incoming bandwidth, usable disks and agreed expansion. Confirm how the actual multi-sensor configuration presents channels; optical views alone do not prove channel use. A recorder that starts full has no spare channels.
Use measured or defensible stream bitrates and the owner’s retention target. The NVR storage guide explains the calculation. Record continuous or event-recording assumptions, audio, free-space allowance and overwrite behaviour. Test what happens to local recording when the approved remote-viewing connection is unavailable.
Make tenant access and handover explicit
Use named accounts and approved roles; a tenant does not automatically get building-wide administration. Have the responsible owner establish purpose, viewing boundaries, notices, retention and disclosure under the applicable rules. The Canadian OPC overt-surveillance guidance concerns private organizations monitoring the public in publicly accessible areas, excluding employee and covert surveillance. Resolve those situations separately rather than treating that guidance as a universal office policy.
Before sign-off, walk the important route with permission, retrieve the event, export a short clip and replay it on the agreed workstation. Use the customer handover checklist to record camera names, approved views, timestamps, firmware, named roles, exact-model documents and fault contacts. Transfer credentials through the agreed secure channel. A property group may reuse useful handover checks across hotels and offices, but guest and tenant boundaries still require separate surveys.
FAQ
How many cameras does a six-storey office need?
There is no useful floor-count rule. Start with entrances, travel routes and agreed evidence tasks, then test proposed positions. Use any sample schedule only as a clearly labelled illustration.
Can one garage camera identify people and read plates?
Do not promise both from an overview. Plate capture, pedestrian detail and general movement can require different positions and settings. Test each requested result at the actual distance and traffic conditions.
Get the schedule reviewed before the quote
Send security camera technical support the approved marked plan, scene distances, staged lighting examples, camera schedule, retention target and IT constraints. Initial design review does not need tenant records or identifiable staff footage. Anabon supports professional installers and integrators; keep the customer relationship and confirm the final site-specific design before quoting.
References
References reviewed October 30, 2026. OPC: Guidelines for Overt Video Surveillance in the Private Sector, page modified March 6, 2008. Its stated scope excludes employee and covert surveillance; applicable local duties still require project review. The exact varifocal model example is supported by CASE catalog physical page 6, not a universal scene-performance guarantee.